Plastics production: Safe pressure measurement around 330 �C

Pressure measurement in the production of PBAT, a biodegradable plastic, faces a particular challenge: Temperatures as high as 330 �C prevail along the way. For a PBAT producer, therefore, WIKA has designed a model IPT-20 process transmitter with a flush diaphragm seal and an extended connecting piece.
Polybutylene adipate terephthalate, PBAT for short, is really a copolymer from the polyester group. The plastic can replace polyethylene and is completely biodegradable. PBAT thus contributes to greater sustainability. Among other activities, it can be used to create protective sheeting for agriculture and gardening, compost bags, shopping bags and medical disposables.
Pressure monitoring during esterification and melt polymerisation
The process steps in production include esterification and melt polymerisation. In both of these processes, WIKA?s customer, a petrochemical company, uses the IPT-20 transmitter for pressure monitoring.
Corresponding to the task, WIKA supplied the instruments with three basic measuring ranges: 0 ? 16 bar, 0 ? เกจวัดแรงดันน้ำ4หุน and 0 ? 250 bar. The exact measuring ranges can be set for this kind of transmitter utilizing the turndown function. Which means that the output signal is distributed only on the scaled range. Thus, the measured values can be more precisely determined.
Handles temperatures around 330 �C: Measuring unit with IPT-20 process transmitter.
Connecting element as a cooling element
Pressure measurement in plastics production regarding PBAT is subject to process temperatures between 100 �C and 330 �C. For this reason, WIKA has designed a measuring unit consisting of an IPT-20, a flush diaphragm seal and a 200 mm long connecting piece. Because of its length, the connecting element acts as a cooling element. Thus, the measuring instrument remains protected against adverse effects caused by the high process temperatures. The entire design is also minimised in volume to reduce any temperature error effects during measurement to a minimum and thus achieve the best possible accuracy.
Plastic is highly viscous at the pressure measurement points
At the measuring points of the IPT-20, the plastic is in an extremely viscous form. The diaphragm seal, combined with the transmitter, is therefore implemented with a flush diaphragm. Because of this, it enables pressure measurement without the threat of media entrapment.
Note
Technical information on the model IPT-20 process transmitter can be found on the WIKA website. There you will also find an overview of other products and solutions for the chemical industry and petrochemical industry sectors, as well as a brochure to download. Assuming you have any questions, your contact will gladly help you.
Also read our posts
Diaphragm seal system with diaphragm monitoring ? also digital
Pressure monitoring in the pharmaceutical industry with a universal instrument
There are also out more concerning the turndown function of WIKA process transmitters in the next video: