What is the leading ignition protection type for UHP pressure transducers?

The leading ignition protection type is critical for the electrical connection of a pressure sensor with explosion protection. It does not necessarily have to be the main one with the stricter requirements. This applies, for example, for the UHP pressure transducers of the WU series from WIKA. They have been designed for used in semiconductor production.
Explosion protection can be an indispensable safety precaution there. Simply because the substances required for manufacturing include highly flammable gases. Consequently, you will find a threat of an explosive atmosphere forming.
Explosion protection concept
UHP pressure transducers for such processes must be designed with the corresponding safety. As well as their small design and specific process connections, the models WUC-1x and WU-2x have a thorough explosion protection concept. The marking of the instruments provides information on this:
II 3G Ex ec ic IIC T6/T5/T4 Gc X
The abbreviations listed in them mean, in greater detail:
II 3G:
Equipment group 2 (all areas except mining), may be used in zone 2 (rare and short-term Ex atmosphere).
Ex ec ic:
Ignition protection types ?ec? (increased safety) and ?ic? (intrinsically safe; zone 2).
?Ex ec? has replaced the ignition protection type ?Ex nA? (non-sparking) because the start of 2022. However, this will not affect the Ex concept of the instruments.
IIC:
Explosion group (here: gases, resistive ignition energy of 40 �J, suitable for hydrogen/acetylene).
T6/T5/T4:
Temperature classes. T6 as the highest requirement means a maximum permissible surface temperature in the Ex environment < 85 �C (max. surface temperature of the WUC-1x and WU-2x: 40 �C).
Gc:
?Equipment Protection Level? (EPL) for zone 2 per IEC 60079-0
X:
Specific requirements which are listed in the operating instructions (for instance, the suitable mating connector).
?ec? may be the leading ignition protection type
It really is noticeable that the marking contains two ignition protection types. However, only 1 is relevant for the electrical connection: the leading ignition protection type. Regarding ส่วนประกอบpressuregauge from the WU series, it is the Ex ec (Ex nA up to 2022) mentioned first rather than the stricter Ex ic. This may also be seen in the bond values in the info sheet and operating instructions. Only the specification of the maximum supply voltage UN = 30 V, that is also stated in the IECEx certificate, is pertinent here.
What does the classification ?Ex ic? stand for? It only pertains to the potentiometer of the transducer. The resistive component has an intrinsically safe circuit and will therefore be adjusted to improve zero drift during operation. In their overall form, the WU models usually do not require an intrinsically safe circuit. However, they must never be disconnected from the circuit during operation or when an Ex atmosphere is present.
Note
Further information on the WUC-1x and WU-2x UHP pressure transducers and about hydrogen can be found on the WIKA website. If you have any questions, your contact will gladly help you.
Also read our articles
Ex protection: The most frequent ignition protection types for sensors in gas hazardous areas
Ex protection: The difference between your zone and division model